Ensure that we have a required_qmax for 'exchanges' not affected by 'one-U-step' rules (mip_quotation.pck).

Tidy-up debug messages from MIP_FILES.pck.

git-svn-id: http://locode01.ad.dom/svn/WEBMIP/trunk@3940 248e525c-4dfb-0310-94bc-949c084e9493
This commit is contained in:
hardya
2008-03-11 12:10:01 +00:00
parent d6f53e6c32
commit b684db635b
2 changed files with 49 additions and 49 deletions

View File

@@ -53,12 +53,12 @@ CREATE OR REPLACE PACKAGE BODY mip_files AS
BEGIN
pl('is_file_over_size_limit:' || p_uri);
pl('is_file_over_size_limit:entry:' || p_uri);
SELECT doc_size
INTO l_file_size
FROM wwv_flow_files
WHERE NAME = p_uri;
pl('l_file_size:' || l_file_size);
pl('is_file_over_size_limit:exit:' || l_file_size);
RETURN(l_file_size > 3 * 1024 * 1024);
END is_file_over_size_limit;
@@ -270,8 +270,7 @@ CREATE OR REPLACE PACKAGE BODY mip_files AS
l_doc_id NUMBER;
l_success BOOLEAN;
BEGIN
pl('set_file_association, p_uri=' || p_uri || ', p_drwg_code=' ||
p_drwg_code);
pl('set_file_association:entry:'|| p_uri || ':'||p_docu_type||':'||p_doro_type);
--reference it in the documents table
INSERT INTO documents
(uri
@@ -319,7 +318,6 @@ CREATE OR REPLACE PACKAGE BODY mip_files AS
,p_description
,doev_seq.NEXTVAL);
pl('check_file_sizes');
IF p_rt_code = 'ENQUIRY SUPPORTING DOC'
AND NOT p_enqu_id IS NULL THEN
IF (are_files_over_size_limit(p_enqu_id) OR
@@ -327,13 +325,13 @@ CREATE OR REPLACE PACKAGE BODY mip_files AS
l_success := delete_file(l_doc_id
,'REMOVED SIZE'
,'webMIP determined the file or files to be too big');
pl('returning false');
pl('set_file_association:exit:false');
RETURN FALSE;
END IF;
END IF;
--if it works then return true
pl('returning true');
pl('set_file_association:exit:true');
RETURN TRUE;
END set_file_association;
/*

View File

@@ -2046,38 +2046,17 @@ RECEIVED AT THIS ADDRESS CANNOT BE RESPONDED TO.');
IF p_enqu.enty_code IN ('INSTALL', 'STD INSTALL') THEN
add_quote_reason(p_enqu.id
,p_reason => 'Attempting an automatic installation quote for ' ||
p_enqu.id || '.' || ' Required SVCP ' ||
p_enqu.required_svcp_code ||
', REQUESTED_MESC_CODE=' ||
p_enqu.required_mesc_code || ', QMAX=' ||
p_enqu.qmax || ', Outlet Pressure=' ||
p_enqu.required_metering_pressure || '.'
p_enqu.id || '.'
,p_internal_or_external => gc_internal_reason);
ELSIF p_enqu.enty_code IN ('EXCHANGE', 'STD EXCHANGE') THEN
add_quote_reason(p_enqu.id
,p_reason => 'Attempting an automatic exchange quote for ' ||
p_enqu.id || '.' || ' Required SVCP ' ||
p_enqu.required_svcp_code ||
', REQUESTED_MESC_CODE=' ||
p_enqu.required_mesc_code || ', QMAX=' ||
p_enqu.qmax || ', Outlet Pressure=' ||
p_enqu.required_metering_pressure || '.' ||
'Existing meter was a ' ||
p_enqu.existing_mesc_code || ' ' ||
p_enqu.existing_mety_code
p_enqu.id || '.'
,p_internal_or_external => gc_internal_reason);
ELSIF p_enqu.enty_code IN ('CHANGE CAPACITY') THEN
add_quote_reason(p_enqu.id
,p_reason => 'Attempting an automatic change capacity quote for ' ||
p_enqu.id || '.' || ' Required SVCP ' ||
p_enqu.required_svcp_code ||
', REQUESTED_MESC_CODE=' ||
p_enqu.required_mesc_code || ', QMAX=' ||
p_enqu.qmax || ', Outlet Pressure=' ||
p_enqu.required_metering_pressure || '.' ||
'Existing meter was a ' ||
p_enqu.existing_mesc_code || ' ' ||
p_enqu.existing_mety_code
p_enqu.id || '.'
,p_internal_or_external => gc_internal_reason);
END IF;
@@ -2089,6 +2068,15 @@ RECEIVED AT THIS ADDRESS CANNOT BE RESPONDED TO.');
l_existing_rec_metr_details.mety_code || ':' ||
l_existing_rec_metr_details.prty_id
,$$PLSQL_LINE);
add_quote_reason('Existing meter details. Meter model is ' ||
nvl(l_existing_rec_metr_details.code
,'UNKNOWN') || ', meter size code is ' ||
nvl(l_existing_rec_metr_details.mesc_code
,'UNKNOWN') || ', meter type is ' ||
nvl(l_existing_rec_metr_details.mety_code
,'UNKNOWN')
,gc_internal_reason);
-- Need to follow the 'site survey' rule:
-- All exchanges require a site survey UNLESS
-- the service pressure is LP and the existing meter is a Diaphragm; OR
@@ -2100,7 +2088,7 @@ RECEIVED AT THIS ADDRESS CANNOT BE RESPONDED TO.');
IF p_enqu.required_svcp_code = 'LP'
AND l_existing_rec_metr_details.mety_code = 'DIAPHRAGM' THEN
-- no restrictions
NULL;
l_required_qmax := p_enqu.qmax;
ELSIF p_enqu.required_svcp_code = 'MP'
AND l_existing_rec_metr_details.mety_code = 'DIAPHRAGM' THEN
-- can quote for specific meter size
@@ -2122,6 +2110,12 @@ RECEIVED AT THIS ADDRESS CANNOT BE RESPONDED TO.');
,'Site Survey is required for exchange of diaphragm meter from size ' ||
l_existing_rec_metr_details.mesc_code || ' to ' ||
l_required_mesc_code || '.');
ELSE
add_quote_reason('Required meter size code is ' ||
l_required_mesc_code
,gc_internal_reason);
pl('Required Meter Size Code=' || l_required_mesc_code
,$$PLSQL_LINE);
END IF;
ELSE
p_manual_or_automatic_quote := gc_manual_quote;
@@ -2146,12 +2140,18 @@ RECEIVED AT THIS ADDRESS CANNOT BE RESPONDED TO.');
IF NOT p_manual_or_automatic_quote = gc_manual_quote THEN
cout_assert.istrue(NOT (l_required_mesc_code IS NULL AND
l_required_qmax IS NULL)
,p_message => 'EITHER required_mesc_code must be null OR required_qmax must be null');
cout_assert.istrue(NOT (l_required_mesc_code IS NOT NULL AND
l_required_qmax IS NOT NULL)
,p_message => 'EITHER required_mesc_code must be null OR required_qmax must be null');
cout_assert.istrue((l_required_mesc_code IS NULL AND
l_required_qmax IS NOT NULL) OR
(l_required_mesc_code IS NOT NULL AND
l_required_qmax IS NULL)
,p_message => 'EITHER l_required_mesc_code must be null OR l_required_qmax must be null');
pl('Looking for modules to match the following: Service Pressure ' ||
p_enqu.required_svcp_code || ', Outlet Pressure ' ||
p_enqu.required_metering_pressure || CASE l_required_mesc_code WHEN NULL THEN
'and required Qmax ' || l_required_qmax ELSE
'and required Meter Size Code ' || l_required_mesc_code
END || '.');
FOR l_rec_module IN (SELECT modu.code AS modu_code
,modu.selling_price AS modu_selling_price
@@ -2752,7 +2752,8 @@ RECEIVED AT THIS ADDRESS CANNOT BE RESPONDED TO.');
l_additional_costs t_rec_additional_costs;
l_existing_rec_metr_details t_rec_metr_details;
BEGIN
pl('produce_labour_only_quotes'
pl('produce_labour_only_quotes:entry:' || p_enqu.id || ':' ||
p_enqu.enty_code
,$$PLSQL_LINE);
cout_assert.istrue(p_enqu.enty_code IN
('REMOVE', 'STD REMOVE', 'ADVERSARIAL', 'OFMAT',
@@ -2763,21 +2764,22 @@ RECEIVED AT THIS ADDRESS CANNOT BE RESPONDED TO.');
cout_assert.isnotnull(l_regi_code
,'Attempted to produce quote for enquiry for a installation postcode (' ||
p_enqu.install_postcode || ') without a region.');
add_quote_reason(p_enqu.id
,p_reason => 'Attempting an automatic labour quote for ' ||
p_enqu.id || '.' || 'Enquiry Code=' ||
p_enqu.enty_code || ', SVCP ' ||
p_enqu.required_svcp_code ||
', Meter Type Code=' ||
p_enqu.existing_mety_code ||
', Meter Size Code=' ||
p_enqu.existing_mesc_code || '.'
,p_internal_or_external => gc_internal_reason);
l_this_is_automatic_quote := TRUE;
l_existing_rec_metr_details := get_existing_metr_details(p_enqu);
add_quote_reason(p_enqu.id
,p_reason => 'Attempting an automatic labour quote for ' ||
p_enqu.id || '.' || 'Enquiry Code=' ||
p_enqu.enty_code || ', SVCP ' ||
p_enqu.required_svcp_code ||
', Meter Type Code=' ||
l_existing_rec_metr_details.mety_code ||
', Meter Size Code=' ||
l_existing_rec_metr_details.mesc_code || '.'
,p_internal_or_external => gc_internal_reason);
l_labour_costs := get_laco(p_enty_code => p_enqu.enty_code
,p_regi_code => l_regi_code
,p_mety_code => l_existing_rec_metr_details.mety_code