Correction to labour cost only quotes to get costing parameters from existing meter (as for module quotes).
git-svn-id: http://locode01.ad.dom/svn/WEBMIP/trunk@3917 248e525c-4dfb-0310-94bc-949c084e9493
This commit is contained in:
@@ -570,8 +570,7 @@ CREATE OR REPLACE PACKAGE BODY mip_quotation IS
|
||||
|
||||
FUNCTION get_system_name RETURN system_configuration.VALUE%TYPE IS
|
||||
BEGIN
|
||||
|
||||
RETURN get_system_configuration_value('SYSTEM_NAME');
|
||||
RETURN 'WEBMIP '|| v('SYSTEM_ENVIRONMENT');
|
||||
END get_system_name;
|
||||
|
||||
FUNCTION get_customer_support_telephone
|
||||
@@ -916,7 +915,6 @@ RECEIVED AT THIS ADDRESS CANNOT BE RESPONDED TO.');
|
||||
al('Phone: 02476 286 322');
|
||||
al('Fax: 02476 286 044');
|
||||
al('Email: ic.nonstandard1@uk.ngrid.com');
|
||||
l_attachment := get_quote_document(p_enqu_id => p_enqu_id);
|
||||
ELSIF p_email_reason = gc_agent_q_acc_notification THEN
|
||||
-- Scenario two: Quotation acceptance notification
|
||||
l_email_subject := get_system_name || ': Quote Acceptance';
|
||||
@@ -1116,8 +1114,6 @@ RECEIVED AT THIS ADDRESS CANNOT BE RESPONDED TO.');
|
||||
END email_agent_mq_available;
|
||||
|
||||
PROCEDURE email_agent_request_for_mq(p_enqu_id IN enquiries.id%TYPE) IS
|
||||
l_system_name system_configuration.VALUE%TYPE := get_system_name;
|
||||
l_quote_row quotes%ROWTYPE;
|
||||
BEGIN
|
||||
pl('email_request_for_mq:enter'
|
||||
,$$PLSQL_LINE);
|
||||
@@ -1882,8 +1878,10 @@ RECEIVED AT THIS ADDRESS CANNOT BE RESPONDED TO.');
|
||||
RETURN t_rec_additional_costs IS
|
||||
l_rec_costs t_rec_additional_costs;
|
||||
BEGIN
|
||||
pl('get_laco'
|
||||
pl('get_laco:entry:' || p_enty_code || ':' || p_regi_code || ':' ||
|
||||
p_mety_code || ':' || p_mesc_code || ':' || p_svcp_code
|
||||
,$$PLSQL_LINE);
|
||||
|
||||
SELECT selling_price
|
||||
,cost_price
|
||||
,delivery_cost
|
||||
@@ -1924,6 +1922,8 @@ RECEIVED AT THIS ADDRESS CANNOT BE RESPONDED TO.');
|
||||
ORDER BY 1)
|
||||
WHERE rownum < 2;
|
||||
|
||||
pl('get_laco:exit:' || l_rec_costs.selling_price);
|
||||
|
||||
RETURN l_rec_costs;
|
||||
|
||||
EXCEPTION
|
||||
@@ -2022,7 +2022,6 @@ RECEIVED AT THIS ADDRESS CANNOT BE RESPONDED TO.');
|
||||
,p_manual_or_automatic_quote IN OUT t_manual_or_automatic_quote) IS
|
||||
l_produced_automatic_quote BOOLEAN;
|
||||
l_this_is_automatic_quote BOOLEAN;
|
||||
l_cannot_quote BOOLEAN;
|
||||
l_regi_code regions.code%TYPE := mip_regions.get_region_for_postcode(p_enqu.install_postcode);
|
||||
l_qute_id quotes.id%TYPE;
|
||||
l_additional_costs t_rec_additional_costs;
|
||||
@@ -2034,8 +2033,9 @@ RECEIVED AT THIS ADDRESS CANNOT BE RESPONDED TO.');
|
||||
pl('produce_module_quotes:entry:' || p_enqu.id || ':' ||
|
||||
p_enqu.enty_code
|
||||
,$$PLSQL_LINE);
|
||||
cout_assert.istrue(p_enqu.enty_code IN ('INSTALL', 'STD INSTALL',
|
||||
'EXCHANGE', 'CAPACITY CHANGE')
|
||||
cout_assert.istrue(p_enqu.enty_code IN
|
||||
('INSTALL', 'STD INSTALL', 'EXCHANGE',
|
||||
'CAPACITY CHANGE', 'STD EXCHANGE')
|
||||
,'Attempted to produce an install or exchange quote for enquiry of type ' ||
|
||||
p_enqu.enty_code);
|
||||
|
||||
@@ -2299,7 +2299,7 @@ RECEIVED AT THIS ADDRESS CANNOT BE RESPONDED TO.');
|
||||
', Meter Type Code:' ||
|
||||
l_rec_module.mety_code ||
|
||||
', Meter Size Code:' ||
|
||||
p_enqu.required_mesc_code ||
|
||||
l_rec_module.mesc_code ||
|
||||
', Service Pressure Code:' ||
|
||||
p_enqu.required_svcp_code || CASE
|
||||
l_regi_code WHEN NULL THEN '' ELSE ' for region code ' || l_regi_code END || '.'
|
||||
@@ -2730,15 +2730,15 @@ RECEIVED AT THIS ADDRESS CANNOT BE RESPONDED TO.');
|
||||
,p_rfq_prty_id IN parties.id%TYPE
|
||||
,p_owner_prty_id IN parties.id%TYPE DEFAULT NULL
|
||||
,p_manual_or_automatic_quote IN OUT t_manual_or_automatic_quote) IS
|
||||
l_produced_automatic_quote BOOLEAN;
|
||||
l_this_is_automatic_quote BOOLEAN;
|
||||
l_regi_code regions.code%TYPE := mip_regions.get_region_for_postcode(p_enqu.install_postcode);
|
||||
l_lead_time NUMBER;
|
||||
l_qute_id quotes.id%TYPE;
|
||||
l_labour_costs t_rec_additional_costs;
|
||||
l_quote_document VARCHAR2(240);
|
||||
l_existing_mesc_code meter_size_codes.code%TYPE;
|
||||
l_additional_costs t_rec_additional_costs;
|
||||
l_produced_automatic_quote BOOLEAN;
|
||||
l_this_is_automatic_quote BOOLEAN;
|
||||
l_regi_code regions.code%TYPE := mip_regions.get_region_for_postcode(p_enqu.install_postcode);
|
||||
l_lead_time NUMBER;
|
||||
l_qute_id quotes.id%TYPE;
|
||||
l_labour_costs t_rec_additional_costs;
|
||||
l_quote_document VARCHAR2(240);
|
||||
l_additional_costs t_rec_additional_costs;
|
||||
l_existing_rec_metr_details t_rec_metr_details;
|
||||
BEGIN
|
||||
pl('produce_labour_only_quotes'
|
||||
,$$PLSQL_LINE);
|
||||
@@ -2764,24 +2764,21 @@ RECEIVED AT THIS ADDRESS CANNOT BE RESPONDED TO.');
|
||||
|
||||
l_this_is_automatic_quote := TRUE;
|
||||
|
||||
l_existing_mesc_code := p_enqu.existing_mesc_code;
|
||||
IF l_existing_mesc_code IS NULL THEN
|
||||
l_existing_mesc_code := get_u_meter_size(p_enqu.qmax);
|
||||
END IF;
|
||||
l_existing_rec_metr_details := get_existing_metr_details(p_enqu);
|
||||
|
||||
l_labour_costs := get_laco(p_enty_code => p_enqu.enty_code
|
||||
,p_regi_code => l_regi_code
|
||||
,p_mety_code => p_enqu.existing_mety_code
|
||||
,p_mesc_code => l_existing_mesc_code
|
||||
,p_mety_code => l_existing_rec_metr_details.mety_code
|
||||
,p_mesc_code => l_existing_rec_metr_details.mesc_code
|
||||
,p_svcp_code => p_enqu.required_svcp_code);
|
||||
IF l_labour_costs.selling_price IS NULL THEN
|
||||
l_this_is_automatic_quote := FALSE;
|
||||
add_quote_reason(p_enqu.id
|
||||
,p_reason => 'Unable to find Labour Cost (selling price) for this Enquiry Type Code: ' ||
|
||||
p_enqu.enty_code || ', Meter Type Code:' ||
|
||||
p_enqu.existing_mety_code ||
|
||||
l_existing_rec_metr_details.mety_code ||
|
||||
', Meter Size Code:' ||
|
||||
l_existing_mesc_code ||
|
||||
l_existing_rec_metr_details.mesc_code ||
|
||||
', Service Pressure Code:' ||
|
||||
p_enqu.required_svcp_code || CASE
|
||||
l_regi_code WHEN NULL THEN '' ELSE ' for region code ' || l_regi_code END || '.'
|
||||
@@ -2790,7 +2787,7 @@ RECEIVED AT THIS ADDRESS CANNOT BE RESPONDED TO.');
|
||||
END IF;
|
||||
|
||||
l_lead_time := get_lead_time(p_enty_code => p_enqu.enty_code
|
||||
,p_mety_code => p_enqu.existing_mety_code
|
||||
,p_mety_code => l_existing_rec_metr_details.mety_code
|
||||
,p_svcp_code => p_enqu.required_svcp_code
|
||||
,p_qmax => p_enqu.qmax);
|
||||
IF l_lead_time IS NULL THEN
|
||||
@@ -2798,7 +2795,7 @@ RECEIVED AT THIS ADDRESS CANNOT BE RESPONDED TO.');
|
||||
add_quote_reason(p_enqu.id
|
||||
,p_reason => 'Unable to find lead time for ' ||
|
||||
get_lead_time_desc(p_enty_code => p_enqu.enty_code
|
||||
,p_mety_code => p_enqu.existing_mety_code
|
||||
,p_mety_code => l_existing_rec_metr_details.mety_code
|
||||
,p_svcp_code => p_enqu.required_svcp_code
|
||||
,p_qmax => p_enqu.qmax)
|
||||
,p_internal_or_external => gc_internal_reason);
|
||||
@@ -2850,8 +2847,8 @@ RECEIVED AT THIS ADDRESS CANNOT BE RESPONDED TO.');
|
||||
,l_qute_id
|
||||
,p_enqu.enty_code
|
||||
,l_labour_costs.svcpt_code
|
||||
,l_existing_mesc_code
|
||||
,p_enqu.existing_mety_code
|
||||
,l_existing_rec_metr_details.mesc_code
|
||||
,l_existing_rec_metr_details.mety_code
|
||||
,l_labour_costs.cost_price
|
||||
,l_labour_costs.selling_price
|
||||
,l_labour_costs.delivery_cost
|
||||
|
||||
Reference in New Issue
Block a user