Alterations to schema (primarily enquiries) to support 'existing' meter requirements due to [wiki:MeetingNotes/MeetingNote3rdMarch Meeting to discuss/spec new variations, 3rd March]

git-svn-id: http://locode01.ad.dom/svn/WEBMIP/trunk@3837 248e525c-4dfb-0310-94bc-949c084e9493
This commit is contained in:
hardya
2008-03-04 15:14:02 +00:00
parent dbcb349c45
commit de1d9d408e
10 changed files with 177 additions and 168 deletions

View File

@@ -1,78 +1,78 @@
COLUMN_NAME ,Appendix Reference,INSTALL,STD INSTALL,OFMAT,EXCHANGE,STD EXCHANGE,REMOVE,STD REMOVE,ADVERSARIAL,ALTERATION,CHANGE CAPACITY,ADDONS(EMS,AMR),OTHER,Notes,DisplaySequence
COLUMN_NAME ,Appendix Reference,INSTALL,STD INSTALL,OFMAT,EXCHANGE,STD EXCHANGE,REMOVE,STD REMOVE,ADVERSARIAL,ALTERATION,CHANGE CAPACITY,"ADDONS(EMS,AMR)",OTHER,Notes,DisplaySequence
ACCESS_ADDITIONAL,Site Detail.Access Instructions,O,O,O,O,O,O,O,O,O,O,O,O,,61
ACCESS_PASSWORD,Site Detail.Access Password,O,O,O,O,O,O,O,O,O,O,O,O,,62
AGENT_COMT_CODE,Supplier Agent.Telephone1/Telephone2/Fax/Email,M,M,M,M,M,M,M,M,M,M,M,M,,68
AGENT_CONTACT_VALUE,Supplier Agent.Telephone1/Telephone2/Fax/Email,M,M,M,M,M,M,M,M,M,M,M,M,,69
ALTY_CODE,Site Detail.Asset Location Code,M,M,M,M,M,M,M,M,M,M,M,M,,64
AMR_REQUIRED,Job Information.Additional Services.AMR,O-M5,O-M5,H,O-M5,O-M5,H,H,H,O-M5,O-M5,O-M5,O-M5,"The AMR may only be available for the Tripartite suppliers or BG, GW to confirm!",25
ANNUAL_QUANTITY,Job Information.Annual Quantity,O,O,O,O,O,H,H,H,O,O,O,O,if > 732 mwh go bespoke,32
ASSET_LOCATION_NOTES,Site Detail.Asset Location Notes,O,O,O,O,O,O,O,O,O,O,O,O,,65
BASE_REQUIRED,Job Information.Additional Services.Base,M,M,H,M,M,H,H,H,M,M,H,M,,26
BYPASS_REQUIRED,Job Information.Additional Services.By-pass,O,O,H,O,O,H,H,H,O,O,O,O,"If yes, warn user if twin stream is no",27
CACA_CODE,Site Detail.Care Category,O,O,O,O,O,O,O,O,O,O,O,O,,66
CONVERTOR_REQUIRED,Job Information.Additional Services.Convertor,M,M,H,M,M,H,H,H,M,M,M,M,this can be an add-on for removals,28
CREATED_ON,,,,,,,,,,,,,,,
DOWNSTREAM_BOOSTER_OR_COMPRESS,Job Information.Booster/Compressor,M,M,M,M,M,H,H,H,M,M,M,M,,34
EMS_REQUIRED,Job Information.Additional Services.EMS,M,M,H,M,M,H,H,H,M,M,M,M,,29
ENTY_CODE,Job Information.Job Type,M,M,M,M,M,M,M,M,M,M,M,M,,43
EXISTING_CONVERTOR,Job Information.Existing Convertor,H,H,O,M,M,M,M,M,O,O,O,O,,72
EXISTING_LOGGER,Job Information.Logger,H,H,H,O,O,O,O,O,O,O,O,O,,71
EXISTING_PRTY_ID,Job Information.Existing Manufacturer,H,H,M,M,M,M,M,M,O,O,O,O,,
EXISTING_MESC_CODE,Job Information.Existing Meter Size,H,H,M,M,M,M,M,M,M,M,O,O,,36
EXISTING_METER_ASSET_PROVIDER,Job Information.Supplier / Job Information.Consumer(Meter Asset Manager),O,O,O,O,O,O,O,O,O,O,O,O,,54
EXISTING_METR_CODE,Job Information.Model Code,H,H,M,M,M,M,M,M,O,O,O,O,,49
EXISTING_METER_OWNER,Job Information.Gas Act Owner,O,O,M,M,M,M,M,M,M,M,M,O,,38
EXISTING_METER_SERIAL_NO,Job Information.Existing Asset Serial Number,H,H,M,M,M,M,M,M,M,M,M,O,,35
EXISTING_METY_CODE,Job Information.Meter Type Existing ,H,H,M,M,M,M,M,M,M,M,O,O,,37
FIRST_ALT_BUILDING,Contact Address.Building,O,O,O,O,O,O,O,O,O,O,O,O,,7
FIRST_ALT_CITY,Contact Address.City,O,O,O,O,O,O,O,O,O,O,O,O,,8
FIRST_ALT_POSTCODE,Contact Address.Post Code,O,O,O,O,O,O,O,O,O,O,O,O,,13
FIRST_ALT_STREET,Contact Address.Street,O,O,O,O,O,O,O,O,O,O,O,O,,19
FIRST_ALT_SUB_BUILDING,Contact Address.Sub Building,O,O,O,O,O,O,O,O,O,O,O,O,,20
FIRST_CONTACT_EMAIL,Contact Address.Email,O,O,O,O,O,O,O,O,O,O,O,O,,9
FIRST_CONTACT_FAX,Contact Address.Fax,O,O,O,O,O,O,O,O,O,O,O,O,,11
FIRST_CONTACT_INITIALS,Contact Address.Contact Initials,O,O,O,O,O,O,O,O,O,O,O,O,,18
FIRST_CONTACT_NAME,Address.Contact Name,M,M,M,M,M,M,M,M,M,M,M,M,,3
FIRST_CONTACT_TELEPHONE_1,Contact Address.Telephone1,M,M,M,M,M,M,M,M,M,M,M,M,,21
FIRST_CONTACT_TELEPHONE_2,Contact Address.Telephone2,O,O,O,O,O,O,O,O,O,O,O,O,,23
FIRST_CONTACT_TITLE,Contact Address.Contact Title,O,O,O,O,O,O,O,O,O,O,O,O,,17
HOUSING_REQUIRED,Job Information.Additional Services.Housing,M,M,H,M,M,H,H,H,M,M,H,M,,30
ID,Enquiry Reference (not in spec appendix),M,M,M,M,M,M,M,M,M,M,M,M,,70
INDICATIVE_DATE,Job Information.Indicative Substantial Completion Date,O,O,O,O,O,O,O,O,O,O,O,O,,39
INDICATIVE_TIME,Job Information.Appointment Preference,O,O,O,O,O,O,O,O,O,O,O,O,,33
INSTALL_BUILDING,Address.Building,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,,1
INSTALL_CITY,Address.City,M,M,M,M,M,M,M,M,M,M,M,M,,2
FIRST_CONTACT_NAME,Address.Contact Name,M,M,M,M,M,M,M,M,M,M,M,M,,3
INSTALL_POSTCODE,Address.Post Code,M,M,M,M,M,M,M,M,M,M,M,M,,4
INSTALL_STREET,Address.Street,M,M,M,M,M,M,M,M,M,M,M,M,,5
INSTALL_SUB_BUILDING,Address.Sub Building,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,,6
FIRST_ALT_BUILDING,Contact Address.Building,O,O,O,O,O,O,O,O,O,O,O,O,,7
FIRST_ALT_CITY,Contact Address.City,O,O,O,O,O,O,O,O,O,O,O,O,,8
FIRST_CONTACT_EMAIL,Contact Address.Email,O,O,O,O,O,O,O,O,O,O,O,O,,9
SECOND_CONTACT_EMAIL,Second Contact Address.Email,O,O,O,O,O,O,O,O,O,O,O,O,,10
FIRST_CONTACT_FAX,Contact Address.Fax,O,O,O,O,O,O,O,O,O,O,O,O,,11
SECOND_CONTACT_FAX,Contact Address.Fax,O,O,O,O,O,O,O,O,O,O,O,O,,12
FIRST_ALT_POSTCODE,Contact Address.Post Code,O,O,O,O,O,O,O,O,O,O,O,O,,13
SECOND_CONTACT_TITLE,Second Contact Address.Contact Title,O,O,O,O,O,O,O,O,O,O,O,O,,14
SECOND_CONTACT_INITIALS,Second Contact Address.Contact Initials,O,O,O,O,O,O,O,O,O,O,O,O,,15
SECOND_CONTACT_NAME,Second Contact Address.Second Contact Name,O,O,O,O,O,O,O,O,O,O,O,O,,16
FIRST_CONTACT_TITLE,Contact Address.Contact Title,O,O,O,O,O,O,O,O,O,O,O,O,,17
FIRST_CONTACT_INITIALS,Contact Address.Contact Initials,O,O,O,O,O,O,O,O,O,O,O,O,,18
FIRST_ALT_STREET,Contact Address.Street,O,O,O,O,O,O,O,O,O,O,O,O,,19
FIRST_ALT_SUB_BUILDING,Contact Address.Sub Building,O,O,O,O,O,O,O,O,O,O,O,O,,20
FIRST_CONTACT_TELEPHONE_1,Contact Address.Telephone1,M,M,M,M,M,M,M,M,M,M,M,M,,21
SECOND_CONTACT_TELEPHONE_1,Contact Address.Telephone1,O,O,O,O,O,O,O,O,O,O,O,O,,22
FIRST_CONTACT_TELEPHONE_2,Contact Address.Telephone2,O,O,O,O,O,O,O,O,O,O,O,O,,23
SECOND_CONTACT_TELEPHONE_2,Contact Address.Telephone2,O,O,O,O,O,O,O,O,O,O,O,O,,24
AMR_REQUIRED,Job Information.Additional Services.AMR,O-M5,O-M5,H,O-M5,O-M5,H,H,H,O-M5,O-M5,O-M5,O-M5,The AMR may only be available for the Tripartite suppliers or BG, GW to confirm!,25
BASE_REQUIRED,Job Information.Additional Services.Base,M,M,H,M,M,H,H,H,M,M,H,M,,26
BYPASS_REQUIRED,Job Information.Additional Services.By-pass,O,O,H,O,O,H,H,H,O,O,O,O,If yes, warn user if twin stream is no,27
CONVERTOR_REQUIRED,Job Information.Additional Services.Convertor,M,M,H,M,M,H,H,H,M,M,M,M,this can be an add-on for removals,28
EMS_REQUIRED,Job Information.Additional Services.EMS,M,M,H,M,M,H,H,H,M,M,M,M,,29
HOUSING_REQUIRED,Job Information.Additional Services.Housing,M,M,H,M,M,H,H,H,M,M,H,M,,30
TWIN_STREAM_REQUIRED,Job Information.Additional Services.Twin Stream,M,M,H,M,M,H,H,H,M,M,H,M,,31
ANNUAL_QUANTITY,Job Information.Annual Quantity,O,O,O,O,O,H,H,H,O,O,O,O,if > 732 mwh go bespoke,32
INDICATIVE_TIME,Job Information.Appointment Preference,O,O,O,O,O,O,O,O,O,O,O,O,,33
DOWNSTREAM_BOOSTER_OR_COMPRESS,Job Information.Booster/Compressor,M,M,M,M,M,H,H,H,M,M,M,M,,34
EXISTING_METER_SERIAL_NO,Job Information.Existing Asset Serial Number,H,H,M,M,M,M,M,M,M,M,M,O,,35
EXISTING_MESC_CODE,Job Information.Existing Meter Size,H,H,M,M,M,M,M,M,M,M,O,O,,36
EXISTING_METY_CODE,Job Information.Meter Type Existing ,H,H,M,M,M,M,M,M,M,M,O,O,,37
EXISTING_METER_OWNER,Job Information.Gas Act Owner,O,O,M,M,M,M,M,M,M,M,M,O,,38
INDICATIVE_DATE,Job Information.Indicative Substantial Completion Date,O,O,O,O,O,O,O,O,O,O,O,O,,39
REQUIRED_IP_DETAILS,Job Information.IP Details,O-M3,H,O-M3,O-M3,H,O-M3,H,O-M3,O-M3,O-M3,O-M3,O-M3,if service pressure is IP,40
REQUIRED_IP_MBAR,Job Information.IP Mbar,O-M3,H,O-M3,O-M3,H,O-M3,H,O-M3,O-M3,O-M3,O-M3,O-M3,if service pressure is IP,41
JOB_DESCRIPTION,Job Information.Job Description,O,O,O,O,O,O,O,O,O,O,O,O,,42
ENTY_CODE,Job Information.Job Type,M,M,M,M,M,M,M,M,M,M,M,M,,43
LOAD_CONTROL_TYPE,Job Information.Load Control Type,M,M,H,M,M,H,H,H,O,M,O,O,,44
MARKET_SECTOR_CODE,Job Information.Market Sector Code,O,O,O,O,O,O,O,O,O,O,O,O,,45
QMAX,Job Information.Measuring Capacity Qmax,M,O-M2,O,M,O-M2,O,O,O,O,M,O,O,,46
QMIN,Job Information.Measuring Capacity Qmin,O,O,O,O,O,O,O,O,O,O,O,O,,47
REQUIRED_MESC_CODE,Job Information.Meter Size,H,O-M2,H,H,O-M2,H,H,H,H,O,H,O,,48
EXISTING_METER_MODEL,Job Information.Model Code,H,H,M,M,M,M,M,M,O,O,O,O,,49
MPRN,Site Detail.MPRN,O-M4,O-M4,M,M,M,M,M,M,M,M,M,O,,67
MPRN_ALT,Site Detail.Additional Information,O-M4,O-M4,O,O,O,O,O,O,O,O,O,O,,63
OTHER_INFORMATION,Job Information.Other Information,O,O,O,O,O,O,O,O,O,O,O,O,,50
OTHER_PROJECT_REFERENCE,Job Information.Other Related Projects,O,O,O,O,O,O,O,O,O,O,O,O,,51
QMAX,Job Information.Measuring Capacity Qmax,M,O-M2,O,M,O-M2,O,O,O,O,M,O,O,,46
QMIN,Job Information.Measuring Capacity Qmin,O,O,O,O,O,O,O,O,O,O,O,O,,47
REQUIRED_IP_DETAILS,Job Information.IP Details,O-M3,H,O-M3,O-M3,H,O-M3,H,O-M3,O-M3,O-M3,O-M3,O-M3,if service pressure is IP,40
REQUIRED_IP_MBAR,Job Information.IP Mbar,O-M3,H,O-M3,O-M3,H,O-M3,H,O-M3,O-M3,O-M3,O-M3,O-M3,if service pressure is IP,41
REQUIRED_MESC_CODE,Job Information.Meter Size,H,O-M2,H,H,O-M2,H,H,H,H,O,H,O,,48
REQUIRED_METERING_PRESSURE,Job Information.Required Meter Pressure,M,M,M,M,M,M,M,M,M,M,O,O,,52
REQUIRED_SVCP_CODE,Job Information.Service Pressure,O-M3,M,O-M3,O-M3,M,O-M3,M,O-M3,O-M3,O-M3,O-M3,O-M3,,53
EXISTING_METER_ASSET_PROVIDER,Job Information.Supplier / Job Information.Consumer(Meter Asset Manager),O,O,O,O,O,O,O,O,O,O,O,O,,54
TRANSACTION_REFERENCE,Job Site Details.Transaction Reference,O,O,O,O,O,O,O,O,O,O,O,O,,55
SECOND_ALT_BUILDING,Second Contact Address.Building,O,O,O,O,O,O,O,O,O,O,O,O,,56
SECOND_ALT_CITY,Second Contact Address.City,O,O,O,O,O,O,O,O,O,O,O,O,,57
SECOND_ALT_POSTCODE,Second Contact Address.Post Code,O,O,O,O,O,O,O,O,O,O,O,O,,58
SECOND_ALT_STREET,Second Contact Address.Street,O,O,O,O,O,O,O,O,O,O,O,O,,59
SECOND_ALT_SUB_BUILDING,Second Contact Address.Sub Building,O,O,O,O,O,O,O,O,O,O,O,O,,60
ACCESS_ADDITIONAL,Site Detail.Access Instructions,O,O,O,O,O,O,O,O,O,O,O,O,,61
ACCESS_PASSWORD,Site Detail.Access Password,O,O,O,O,O,O,O,O,O,O,O,O,,62
MPRN_ALT,Site Detail.Additional Information,O-M4,O-M4,O,O,O,O,O,O,O,O,O,O,,63
ALTY_CODE,Site Detail.Asset Location Code,M,M,M,M,M,M,M,M,M,M,M,M,,64
ASSET_LOCATION_NOTES,Site Detail.Asset Location Notes,O,O,O,O,O,O,O,O,O,O,O,O,,65
CACA_CODE,Site Detail.Care Category,O,O,O,O,O,O,O,O,O,O,O,O,,66
MPRN,Site Detail.MPRN,O-M4,O-M4,M,M,M,M,M,M,M,M,M,O,,67
AGENT_COMT_CODE,Supplier Agent.Telephone1/Telephone2/Fax/Email,M,M,M,M,M,M,M,M,M,M,M,M,,68
AGENT_CONTACT_VALUE,Supplier Agent.Telephone1/Telephone2/Fax/Email,M,M,M,M,M,M,M,M,M,M,M,M,,69
ID,Enquiry Reference (not in spec appendix),M,M,M,M,M,M,M,M,M,M,M,M,,70
EXISTING_LOGGER,Job Information.Logger,H,H,H,O,O,O,O,O,O,O,O,O,,71
EXISTING_CONVERTOR,Job Information.Existing Convertor,H,H,O,M,M,M,M,M,O,O,O,O,,72
EXISTING_MANUFACTURER,Job Information.Existing Manufacturer,H,H,M,M,M,M,M,M,O,O,O,O,,
CREATED_ON,,,,,,,,,,,,,,,
SECOND_CONTACT_EMAIL,Second Contact Address.Email,O,O,O,O,O,O,O,O,O,O,O,O,,10
SECOND_CONTACT_FAX,Contact Address.Fax,O,O,O,O,O,O,O,O,O,O,O,O,,12
SECOND_CONTACT_INITIALS,Second Contact Address.Contact Initials,O,O,O,O,O,O,O,O,O,O,O,O,,15
SECOND_CONTACT_NAME,Second Contact Address.Second Contact Name,O,O,O,O,O,O,O,O,O,O,O,O,,16
SECOND_CONTACT_TELEPHONE_1,Contact Address.Telephone1,O,O,O,O,O,O,O,O,O,O,O,O,,22
SECOND_CONTACT_TELEPHONE_2,Contact Address.Telephone2,O,O,O,O,O,O,O,O,O,O,O,O,,24
SECOND_CONTACT_TITLE,Second Contact Address.Contact Title,O,O,O,O,O,O,O,O,O,O,O,O,,14
TRANSACTION_REFERENCE,Job Site Details.Transaction Reference,O,O,O,O,O,O,O,O,O,O,O,O,,55
TWIN_STREAM_REQUIRED,Job Information.Additional Services.Twin Stream,M,M,H,M,M,H,H,H,M,M,H,M,,31
UPDATED_BY,,,,,,,,,,,,,,,
UPDATED_ON,,,,,,,,,,,,,,,
,,,,,,,,,,,,,,,
1 COLUMN_NAME ,Appendix Reference,INSTALL,STD INSTALL,OFMAT,EXCHANGE,STD EXCHANGE,REMOVE,STD REMOVE,ADVERSARIAL,ALTERATION,CHANGE CAPACITY,ADDONS(EMS,AMR),OTHER,Notes,DisplaySequence COLUMN_NAME Appendix Reference INSTALL STD INSTALL OFMAT EXCHANGE STD EXCHANGE REMOVE STD REMOVE ADVERSARIAL ALTERATION CHANGE CAPACITY ADDONS(EMS,AMR) OTHER Notes DisplaySequence
2 ACCESS_ADDITIONAL Site Detail.Access Instructions O O O O O O O O O O O O 61
3 ACCESS_PASSWORD Site Detail.Access Password O O O O O O O O O O O O 62
4 AGENT_COMT_CODE Supplier Agent.Telephone1/Telephone2/Fax/Email M M M M M M M M M M M M 68
5 AGENT_CONTACT_VALUE Supplier Agent.Telephone1/Telephone2/Fax/Email M M M M M M M M M M M M 69
6 ALTY_CODE Site Detail.Asset Location Code M M M M M M M M M M M M 64
7 AMR_REQUIRED Job Information.Additional Services.AMR O-M5 O-M5 H O-M5 O-M5 H H H O-M5 O-M5 O-M5 O-M5 The AMR may only be available for the Tripartite suppliers or BG, GW to confirm! 25
8 ANNUAL_QUANTITY Job Information.Annual Quantity O O O O O H H H O O O O if > 732 mwh go bespoke 32
9 ASSET_LOCATION_NOTES Site Detail.Asset Location Notes O O O O O O O O O O O O 65
10 BASE_REQUIRED Job Information.Additional Services.Base M M H M M H H H M M H M 26
11 BYPASS_REQUIRED Job Information.Additional Services.By-pass O O H O O H H H O O O O If yes, warn user if twin stream is no 27
12 CACA_CODE Site Detail.Care Category O O O O O O O O O O O O 66
13 CONVERTOR_REQUIRED Job Information.Additional Services.Convertor M M H M M H H H M M M M this can be an add-on for removals 28
14 CREATED_ON
15 DOWNSTREAM_BOOSTER_OR_COMPRESS Job Information.Booster/Compressor M M M M M H H H M M M M 34
16 EMS_REQUIRED Job Information.Additional Services.EMS M M H M M H H H M M M M 29
17 ENTY_CODE Job Information.Job Type M M M M M M M M M M M M 43
18 EXISTING_CONVERTOR Job Information.Existing Convertor H H O M M M M M O O O O 72
19 EXISTING_LOGGER Job Information.Logger H H H O O O O O O O O O 71
20 EXISTING_PRTY_ID Job Information.Existing Manufacturer H H M M M M M M O O O O
21 EXISTING_MESC_CODE Job Information.Existing Meter Size H H M M M M M M M M O O 36
22 EXISTING_METER_ASSET_PROVIDER Job Information.Supplier / Job Information.Consumer(Meter Asset Manager) O O O O O O O O O O O O 54
23 EXISTING_METR_CODE Job Information.Model Code H H M M M M M M O O O O 49
24 EXISTING_METER_OWNER Job Information.Gas Act Owner O O M M M M M M M M M O 38
25 EXISTING_METER_SERIAL_NO Job Information.Existing Asset Serial Number H H M M M M M M M M M O 35
26 EXISTING_METY_CODE Job Information.Meter Type Existing H H M M M M M M M M O O 37
27 FIRST_ALT_BUILDING Contact Address.Building O O O O O O O O O O O O 7
28 FIRST_ALT_CITY Contact Address.City O O O O O O O O O O O O 8
29 FIRST_ALT_POSTCODE Contact Address.Post Code O O O O O O O O O O O O 13
30 FIRST_ALT_STREET Contact Address.Street O O O O O O O O O O O O 19
31 FIRST_ALT_SUB_BUILDING Contact Address.Sub Building O O O O O O O O O O O O 20
32 FIRST_CONTACT_EMAIL Contact Address.Email O O O O O O O O O O O O 9
33 FIRST_CONTACT_FAX Contact Address.Fax O O O O O O O O O O O O 11
34 FIRST_CONTACT_INITIALS Contact Address.Contact Initials O O O O O O O O O O O O 18
35 FIRST_CONTACT_NAME Address.Contact Name M M M M M M M M M M M M 3
36 FIRST_CONTACT_TELEPHONE_1 Contact Address.Telephone1 M M M M M M M M M M M M 21
37 FIRST_CONTACT_TELEPHONE_2 Contact Address.Telephone2 O O O O O O O O O O O O 23
38 FIRST_CONTACT_TITLE Contact Address.Contact Title O O O O O O O O O O O O 17
39 HOUSING_REQUIRED Job Information.Additional Services.Housing M M H M M H H H M M H M 30
40 ID Enquiry Reference (not in spec appendix) M M M M M M M M M M M M 70
41 INDICATIVE_DATE Job Information.Indicative Substantial Completion Date O O O O O O O O O O O O 39
42 INDICATIVE_TIME Job Information.Appointment Preference O O O O O O O O O O O O 33
43 INSTALL_BUILDING,Address.Building,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,,1 INSTALL_BUILDING Address.Building O-M1 O-M1 O-M1 O-M1 O-M1 O-M1 O-M1 O-M1 O-M1 O-M1 O-M1 O-M1 1
44 INSTALL_CITY,Address.City,M,M,M,M,M,M,M,M,M,M,M,M,,2 INSTALL_CITY Address.City M M M M M M M M M M M M 2
FIRST_CONTACT_NAME,Address.Contact Name,M,M,M,M,M,M,M,M,M,M,M,M,,3
45 INSTALL_POSTCODE,Address.Post Code,M,M,M,M,M,M,M,M,M,M,M,M,,4 INSTALL_POSTCODE Address.Post Code M M M M M M M M M M M M 4
46 INSTALL_STREET,Address.Street,M,M,M,M,M,M,M,M,M,M,M,M,,5 INSTALL_STREET Address.Street M M M M M M M M M M M M 5
47 INSTALL_SUB_BUILDING,Address.Sub Building,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,,6 INSTALL_SUB_BUILDING Address.Sub Building O-M1 O-M1 O-M1 O-M1 O-M1 O-M1 O-M1 O-M1 O-M1 O-M1 O-M1 O-M1 6
FIRST_ALT_BUILDING,Contact Address.Building,O,O,O,O,O,O,O,O,O,O,O,O,,7
FIRST_ALT_CITY,Contact Address.City,O,O,O,O,O,O,O,O,O,O,O,O,,8
FIRST_CONTACT_EMAIL,Contact Address.Email,O,O,O,O,O,O,O,O,O,O,O,O,,9
SECOND_CONTACT_EMAIL,Second Contact Address.Email,O,O,O,O,O,O,O,O,O,O,O,O,,10
FIRST_CONTACT_FAX,Contact Address.Fax,O,O,O,O,O,O,O,O,O,O,O,O,,11
SECOND_CONTACT_FAX,Contact Address.Fax,O,O,O,O,O,O,O,O,O,O,O,O,,12
FIRST_ALT_POSTCODE,Contact Address.Post Code,O,O,O,O,O,O,O,O,O,O,O,O,,13
SECOND_CONTACT_TITLE,Second Contact Address.Contact Title,O,O,O,O,O,O,O,O,O,O,O,O,,14
SECOND_CONTACT_INITIALS,Second Contact Address.Contact Initials,O,O,O,O,O,O,O,O,O,O,O,O,,15
SECOND_CONTACT_NAME,Second Contact Address.Second Contact Name,O,O,O,O,O,O,O,O,O,O,O,O,,16
FIRST_CONTACT_TITLE,Contact Address.Contact Title,O,O,O,O,O,O,O,O,O,O,O,O,,17
FIRST_CONTACT_INITIALS,Contact Address.Contact Initials,O,O,O,O,O,O,O,O,O,O,O,O,,18
FIRST_ALT_STREET,Contact Address.Street,O,O,O,O,O,O,O,O,O,O,O,O,,19
FIRST_ALT_SUB_BUILDING,Contact Address.Sub Building,O,O,O,O,O,O,O,O,O,O,O,O,,20
FIRST_CONTACT_TELEPHONE_1,Contact Address.Telephone1,M,M,M,M,M,M,M,M,M,M,M,M,,21
SECOND_CONTACT_TELEPHONE_1,Contact Address.Telephone1,O,O,O,O,O,O,O,O,O,O,O,O,,22
FIRST_CONTACT_TELEPHONE_2,Contact Address.Telephone2,O,O,O,O,O,O,O,O,O,O,O,O,,23
SECOND_CONTACT_TELEPHONE_2,Contact Address.Telephone2,O,O,O,O,O,O,O,O,O,O,O,O,,24
AMR_REQUIRED,Job Information.Additional Services.AMR,O-M5,O-M5,H,O-M5,O-M5,H,H,H,O-M5,O-M5,O-M5,O-M5,The AMR may only be available for the Tripartite suppliers or BG, GW to confirm!,25
BASE_REQUIRED,Job Information.Additional Services.Base,M,M,H,M,M,H,H,H,M,M,H,M,,26
BYPASS_REQUIRED,Job Information.Additional Services.By-pass,O,O,H,O,O,H,H,H,O,O,O,O,If yes, warn user if twin stream is no,27
CONVERTOR_REQUIRED,Job Information.Additional Services.Convertor,M,M,H,M,M,H,H,H,M,M,M,M,this can be an add-on for removals,28
EMS_REQUIRED,Job Information.Additional Services.EMS,M,M,H,M,M,H,H,H,M,M,M,M,,29
HOUSING_REQUIRED,Job Information.Additional Services.Housing,M,M,H,M,M,H,H,H,M,M,H,M,,30
TWIN_STREAM_REQUIRED,Job Information.Additional Services.Twin Stream,M,M,H,M,M,H,H,H,M,M,H,M,,31
ANNUAL_QUANTITY,Job Information.Annual Quantity,O,O,O,O,O,H,H,H,O,O,O,O,if > 732 mwh go bespoke,32
INDICATIVE_TIME,Job Information.Appointment Preference,O,O,O,O,O,O,O,O,O,O,O,O,,33
DOWNSTREAM_BOOSTER_OR_COMPRESS,Job Information.Booster/Compressor,M,M,M,M,M,H,H,H,M,M,M,M,,34
EXISTING_METER_SERIAL_NO,Job Information.Existing Asset Serial Number,H,H,M,M,M,M,M,M,M,M,M,O,,35
EXISTING_MESC_CODE,Job Information.Existing Meter Size,H,H,M,M,M,M,M,M,M,M,O,O,,36
EXISTING_METY_CODE,Job Information.Meter Type Existing ,H,H,M,M,M,M,M,M,M,M,O,O,,37
EXISTING_METER_OWNER,Job Information.Gas Act Owner,O,O,M,M,M,M,M,M,M,M,M,O,,38
INDICATIVE_DATE,Job Information.Indicative Substantial Completion Date,O,O,O,O,O,O,O,O,O,O,O,O,,39
REQUIRED_IP_DETAILS,Job Information.IP Details,O-M3,H,O-M3,O-M3,H,O-M3,H,O-M3,O-M3,O-M3,O-M3,O-M3,if service pressure is IP,40
REQUIRED_IP_MBAR,Job Information.IP Mbar,O-M3,H,O-M3,O-M3,H,O-M3,H,O-M3,O-M3,O-M3,O-M3,O-M3,if service pressure is IP,41
48 JOB_DESCRIPTION,Job Information.Job Description,O,O,O,O,O,O,O,O,O,O,O,O,,42 JOB_DESCRIPTION Job Information.Job Description O O O O O O O O O O O O 42
ENTY_CODE,Job Information.Job Type,M,M,M,M,M,M,M,M,M,M,M,M,,43
49 LOAD_CONTROL_TYPE,Job Information.Load Control Type,M,M,H,M,M,H,H,H,O,M,O,O,,44 LOAD_CONTROL_TYPE Job Information.Load Control Type M M H M M H H H O M O O 44
50 MARKET_SECTOR_CODE,Job Information.Market Sector Code,O,O,O,O,O,O,O,O,O,O,O,O,,45 MARKET_SECTOR_CODE Job Information.Market Sector Code O O O O O O O O O O O O 45
51 QMAX,Job Information.Measuring Capacity Qmax,M,O-M2,O,M,O-M2,O,O,O,O,M,O,O,,46 MPRN Site Detail.MPRN O-M4 O-M4 M M M M M M M M M O 67
52 QMIN,Job Information.Measuring Capacity Qmin,O,O,O,O,O,O,O,O,O,O,O,O,,47 MPRN_ALT Site Detail.Additional Information O-M4 O-M4 O O O O O O O O O O 63
REQUIRED_MESC_CODE,Job Information.Meter Size,H,O-M2,H,H,O-M2,H,H,H,H,O,H,O,,48
EXISTING_METER_MODEL,Job Information.Model Code,H,H,M,M,M,M,M,M,O,O,O,O,,49
53 OTHER_INFORMATION,Job Information.Other Information,O,O,O,O,O,O,O,O,O,O,O,O,,50 OTHER_INFORMATION Job Information.Other Information O O O O O O O O O O O O 50
54 OTHER_PROJECT_REFERENCE,Job Information.Other Related Projects,O,O,O,O,O,O,O,O,O,O,O,O,,51 OTHER_PROJECT_REFERENCE Job Information.Other Related Projects O O O O O O O O O O O O 51
55 QMAX Job Information.Measuring Capacity Qmax M O-M2 O M O-M2 O O O O M O O 46
56 QMIN Job Information.Measuring Capacity Qmin O O O O O O O O O O O O 47
57 REQUIRED_IP_DETAILS Job Information.IP Details O-M3 H O-M3 O-M3 H O-M3 H O-M3 O-M3 O-M3 O-M3 O-M3 if service pressure is IP 40
58 REQUIRED_IP_MBAR Job Information.IP Mbar O-M3 H O-M3 O-M3 H O-M3 H O-M3 O-M3 O-M3 O-M3 O-M3 if service pressure is IP 41
59 REQUIRED_MESC_CODE Job Information.Meter Size H O-M2 H H O-M2 H H H H O H O 48
60 REQUIRED_METERING_PRESSURE,Job Information.Required Meter Pressure,M,M,M,M,M,M,M,M,M,M,O,O,,52 REQUIRED_METERING_PRESSURE Job Information.Required Meter Pressure M M M M M M M M M M O O 52
61 REQUIRED_SVCP_CODE,Job Information.Service Pressure,O-M3,M,O-M3,O-M3,M,O-M3,M,O-M3,O-M3,O-M3,O-M3,O-M3,,53 REQUIRED_SVCP_CODE Job Information.Service Pressure O-M3 M O-M3 O-M3 M O-M3 M O-M3 O-M3 O-M3 O-M3 O-M3 53
EXISTING_METER_ASSET_PROVIDER,Job Information.Supplier / Job Information.Consumer(Meter Asset Manager),O,O,O,O,O,O,O,O,O,O,O,O,,54
TRANSACTION_REFERENCE,Job Site Details.Transaction Reference,O,O,O,O,O,O,O,O,O,O,O,O,,55
62 SECOND_ALT_BUILDING,Second Contact Address.Building,O,O,O,O,O,O,O,O,O,O,O,O,,56 SECOND_ALT_BUILDING Second Contact Address.Building O O O O O O O O O O O O 56
63 SECOND_ALT_CITY,Second Contact Address.City,O,O,O,O,O,O,O,O,O,O,O,O,,57 SECOND_ALT_CITY Second Contact Address.City O O O O O O O O O O O O 57
64 SECOND_ALT_POSTCODE,Second Contact Address.Post Code,O,O,O,O,O,O,O,O,O,O,O,O,,58 SECOND_ALT_POSTCODE Second Contact Address.Post Code O O O O O O O O O O O O 58
65 SECOND_ALT_STREET,Second Contact Address.Street,O,O,O,O,O,O,O,O,O,O,O,O,,59 SECOND_ALT_STREET Second Contact Address.Street O O O O O O O O O O O O 59
66 SECOND_ALT_SUB_BUILDING,Second Contact Address.Sub Building,O,O,O,O,O,O,O,O,O,O,O,O,,60 SECOND_ALT_SUB_BUILDING Second Contact Address.Sub Building O O O O O O O O O O O O 60
67 ACCESS_ADDITIONAL,Site Detail.Access Instructions,O,O,O,O,O,O,O,O,O,O,O,O,,61 SECOND_CONTACT_EMAIL Second Contact Address.Email O O O O O O O O O O O O 10
68 ACCESS_PASSWORD,Site Detail.Access Password,O,O,O,O,O,O,O,O,O,O,O,O,,62 SECOND_CONTACT_FAX Contact Address.Fax O O O O O O O O O O O O 12
69 MPRN_ALT,Site Detail.Additional Information,O-M4,O-M4,O,O,O,O,O,O,O,O,O,O,,63 SECOND_CONTACT_INITIALS Second Contact Address.Contact Initials O O O O O O O O O O O O 15
70 ALTY_CODE,Site Detail.Asset Location Code,M,M,M,M,M,M,M,M,M,M,M,M,,64 SECOND_CONTACT_NAME Second Contact Address.Second Contact Name O O O O O O O O O O O O 16
71 ASSET_LOCATION_NOTES,Site Detail.Asset Location Notes,O,O,O,O,O,O,O,O,O,O,O,O,,65 SECOND_CONTACT_TELEPHONE_1 Contact Address.Telephone1 O O O O O O O O O O O O 22
72 CACA_CODE,Site Detail.Care Category,O,O,O,O,O,O,O,O,O,O,O,O,,66 SECOND_CONTACT_TELEPHONE_2 Contact Address.Telephone2 O O O O O O O O O O O O 24
73 MPRN,Site Detail.MPRN,O-M4,O-M4,M,M,M,M,M,M,M,M,M,O,,67 SECOND_CONTACT_TITLE Second Contact Address.Contact Title O O O O O O O O O O O O 14
74 AGENT_COMT_CODE,Supplier Agent.Telephone1/Telephone2/Fax/Email,M,M,M,M,M,M,M,M,M,M,M,M,,68 TRANSACTION_REFERENCE Job Site Details.Transaction Reference O O O O O O O O O O O O 55
75 AGENT_CONTACT_VALUE,Supplier Agent.Telephone1/Telephone2/Fax/Email,M,M,M,M,M,M,M,M,M,M,M,M,,69 TWIN_STREAM_REQUIRED Job Information.Additional Services.Twin Stream M M H M M H H H M M H M 31
ID,Enquiry Reference (not in spec appendix),M,M,M,M,M,M,M,M,M,M,M,M,,70
EXISTING_LOGGER,Job Information.Logger,H,H,H,O,O,O,O,O,O,O,O,O,,71
EXISTING_CONVERTOR,Job Information.Existing Convertor,H,H,O,M,M,M,M,M,O,O,O,O,,72
EXISTING_MANUFACTURER,Job Information.Existing Manufacturer,H,H,M,M,M,M,M,M,O,O,O,O,,
CREATED_ON,,,,,,,,,,,,,,,
76 UPDATED_BY,,,,,,,,,,,,,,, UPDATED_BY
77 UPDATED_ON,,,,,,,,,,,,,,, UPDATED_ON
78 ,,,,,,,,,,,,,,,

View File

@@ -11,14 +11,9 @@ code
,valid_for_new_meter
)
BEGINDATA
U16|U16|16|YES|YES
U25|U25|25|YES|YES
U40|U40|40|YES|YES
U65|U65|65|YES|YES
U100|U100|100|YES|YES
U160|U160|160|YES|YES
Rotary/Turbine 2inch|Rotary/Turbine 2inch|999|YES|NO
Rotary/Turbine 3inch|Rotary/Turbine 3inch|9999|YES|NO
Rotary/Turbine 4inch|Rotary/Turbine 4inch|99999|YES|NO
Rotary/Turbine 6inch|Rotary/Turbine 6inch|999999|YES|NO
Other|Other|9999999|YES|YES
U16|U16|12.8|YES|YES
U25|U25|20|YES|YES
U40|U40|32|YES|YES
U65|U65|52|YES|YES
U100|U100|80|YES|YES
U160|U160|128|YES|YES

View File

@@ -26,7 +26,7 @@ END mip_bulk_load;
/
CREATE OR REPLACE PACKAGE BODY mip_bulk_load IS
g_unknown_manufacturer_id parties.id%TYPE;
g_other_manufacturer_id parties.id%TYPE;
PROCEDURE pl(p_in IN VARCHAR2) IS
BEGIN
@@ -59,9 +59,9 @@ CREATE OR REPLACE PACKAGE BODY mip_bulk_load IS
BEGIN
SELECT id
INTO g_unknown_manufacturer_id
INTO g_other_manufacturer_id
FROM parties
WHERE NAME = 'UNKNOWN'
WHERE NAME = 'OTHER'
AND prty_type = 'MANU';
EXCEPTION
WHEN no_data_found THEN
@@ -75,13 +75,13 @@ CREATE OR REPLACE PACKAGE BODY mip_bulk_load IS
,created_by)
VALUES
(prty_seq.NEXTVAL
,'UNKNOWN'
,'UNKNOWN'
,'Unknown Manufacturer - inserted for bulk load'
,'OTHER'
,'OTHER'
,'Other Manufacturer'
,'MANU'
,SYSDATE
,USER)
RETURNING id INTO g_unknown_manufacturer_id;
RETURNING id INTO g_other_manufacturer_id;
END;
BEGIN
@@ -90,7 +90,43 @@ CREATE OR REPLACE PACKAGE BODY mip_bulk_load IS
,description)
VALUES
('UNKNOWN'
,'Unknown Meter Type - inserted for bulk load');
,'Unknown Meter Type');
EXCEPTION
WHEN dup_val_on_index THEN
NULL;
END;
BEGIN
INSERT INTO meter_size_codes
(code
,description
,qmax
,valid_for_existing_meter
,valid_for_new_meter)
VALUES
('OTHER'
,'Other Meter Size'
,0
,'YES'
,'YES');
EXCEPTION
WHEN dup_val_on_index THEN
NULL;
END;
BEGIN
INSERT INTO meters
(code
,mesc_code
,mety_code
,prty_id
,valid_from)
VALUES
('OTHER'
,'OTHER'
,'UNKNOWN'
,g_other_manufacturer_id
,SYSDATE);
EXCEPTION
WHEN dup_val_on_index THEN
NULL;
@@ -102,7 +138,7 @@ CREATE OR REPLACE PACKAGE BODY mip_bulk_load IS
,description)
VALUES
('UNKNOWN'
,'Unknown Housing Type - inserted for bulk load');
,'Unknown Housing Type');
EXCEPTION
WHEN dup_val_on_index THEN
NULL;
@@ -114,7 +150,7 @@ CREATE OR REPLACE PACKAGE BODY mip_bulk_load IS
,description)
VALUES
('UNKNOWN'
,'Unknown Regulator Type - inserted for bulk load');
,'Unknown Regulator Type');
EXCEPTION
WHEN dup_val_on_index THEN
NULL;
@@ -126,7 +162,7 @@ CREATE OR REPLACE PACKAGE BODY mip_bulk_load IS
,description)
VALUES
('UNKNOWN'
,'Unknown Filter Type - inserted for bulk load');
,'Unknown Filter Type');
EXCEPTION
WHEN dup_val_on_index THEN
NULL;
@@ -138,7 +174,7 @@ CREATE OR REPLACE PACKAGE BODY mip_bulk_load IS
,description)
VALUES
('UNKNOWN'
,'Unknown Relief Valve Type - inserted for bulk load');
,'Unknown Relief Valve Type');
EXCEPTION
WHEN dup_val_on_index THEN
NULL;
@@ -162,7 +198,7 @@ CREATE OR REPLACE PACKAGE BODY mip_bulk_load IS
,description)
VALUES
('UNKNOWN'
,'Unknown Slamshut Type - inserted for bulk load');
,'Unknown Slamshut Type ');
EXCEPTION
WHEN dup_val_on_index THEN
NULL;
@@ -186,7 +222,7 @@ CREATE OR REPLACE PACKAGE BODY mip_bulk_load IS
,description)
VALUES
('UNKNOWN'
,'Unknown Service Pressure Type - inserted for bulk load');
,'Unknown Service Pressure Type ');
EXCEPTION
WHEN dup_val_on_index THEN
NULL;
@@ -198,25 +234,12 @@ CREATE OR REPLACE PACKAGE BODY mip_bulk_load IS
,description)
VALUES
('UNKNOWN'
,'Unknown Drawing - inserted for bulk load');
,'Unknown Drawing ');
EXCEPTION
WHEN dup_val_on_index THEN
NULL;
END;
/* BEGIN
INSERT INTO meter_size_codes
(code
,description
,QMAX,valid_for_existing_meter,valid_for_new_meter)
VALUES
('UNKNOWN'
,'Unknown Meter Size - inserted for bulk load'
,0,'NO','NO');
EXCEPTION
WHEN dup_val_on_index THEN
NULL;
END;*/
END get_globals;
PROCEDURE load_meters IS
@@ -471,43 +494,6 @@ CREATE OR REPLACE PACKAGE BODY mip_bulk_load IS
pl(to_char(SQL%ROWCOUNT
,'FM099G999G999') || ': manufacturers');
/*-- Meters
INSERT INTO meters
(code
,mety_code
,prty_id
,dim_a
,dim_b
,dim_c
,centres
,weight
,qmax
,qmin
,qnom
,valid_from
,mesc_code)
(SELECT code
,'UNKNOWN'
,g_unknown_manufacturer_id
,999
,999
,999
,999
,999
,.999
,.999
,.999
,trunc(SYSDATE)
,'UNKNOWN'
FROM (SELECT DISTINCT nvl(upper(TRIM(metr_code))
,'UNKNOWN') AS code
FROM ext_modules)
WHERE code NOT IN (SELECT code
FROM meters));
pl(to_char(SQL%ROWCOUNT
,'FM099G999G999') || ': meters');
*/
-- Relief valves
INSERT INTO relief_valves
(code
@@ -613,7 +599,7 @@ CREATE OR REPLACE PACKAGE BODY mip_bulk_load IS
(SELECT code
,'UNKNOWN'
,'UNKNOWN'
,g_unknown_manufacturer_id
,g_other_manufacturer_id
,code
,999
,999

View File

@@ -1347,10 +1347,13 @@ RECEIVED AT THIS ADDRESS CANNOT BE RESPONDED TO.');
INTO l_svcpt_code
FROM service_pressures
WHERE code = p_enqu.required_svcp_code;
IF l_svcpt_code <> 'MP' THEN
IF l_svcpt_code = 'LP' THEN
p_manual_or_automatic_quote := gc_automatic_quote;
ELSIF l_svcpt_code <> 'MP' THEN
p_manual_or_automatic_quote := gc_manual_quote;
add_quote_reason(p_enqu.id
,'Site Survey is required for exchange of an existing non-MP meter.');
,'Site Survey is required for exchange of an existing ' ||
l_svcpt_code || ' meter.');
ELSE
-- Exchange, MP
IF p_enqu.existing_mety_code <> 'DIAPHRAGM' THEN

View File

@@ -1,6 +1,6 @@
-- C:\Andy\svn\WEBMIP\Schema\mip.con
--
-- Generated for Oracle 10g on Tue Mar 04 11:30:31 2008 by Server Generator 10.1.2.6.18
-- Generated for Oracle 10g on Tue Mar 04 13:44:17 2008 by Server Generator 10.1.2.6.18
PROMPT Creating Primary Key on 'SYSTEM_CONFIGURATION'
ALTER TABLE SYSTEM_CONFIGURATION
@@ -511,12 +511,12 @@ ALTER TABLE REGI_ENQU_EXCLUSIONS
PROMPT Creating Check Constraint on 'METER_SIZE_CODES'
ALTER TABLE METER_SIZE_CODES
ADD (CONSTRAINT AVCON_1204630230_VALID_000 CHECK (VALID_FOR_EXISTING_METER IN ('YES', 'NO')))
ADD (CONSTRAINT AVCON_1204638256_VALID_000 CHECK (VALID_FOR_EXISTING_METER IN ('YES', 'NO')))
/
PROMPT Creating Check Constraint on 'METER_SIZE_CODES'
ALTER TABLE METER_SIZE_CODES
ADD (CONSTRAINT AVCON_1204630230_VALID_001 CHECK (VALID_FOR_NEW_METER IN ('YES', 'NO')))
ADD (CONSTRAINT AVCON_1204638256_VALID_001 CHECK (VALID_FOR_NEW_METER IN ('YES', 'NO')))
/
PROMPT Creating Check Constraint on 'COSTS'
@@ -552,18 +552,18 @@ ALTER TABLE COSTS
PROMPT Creating Check Constraint on 'COSTS'
ALTER TABLE COSTS
ADD (CONSTRAINT AVCON_1204630230_COST__000 CHECK (COST_TYPE
ADD (CONSTRAINT AVCON_1204638256_COST__000 CHECK (COST_TYPE
IN ('LACO', 'BACO', 'MOCO', 'MECO', 'AICO', 'HOCO', 'COST')))
/
PROMPT Creating Check Constraint on 'DOCUMENTS'
ALTER TABLE DOCUMENTS
ADD (CONSTRAINT AVCON_1204630230_DOCU__000 CHECK (DOCU_TYPE IN ('DOCU', 'INDO', 'EXDO', 'FIDO')))
ADD (CONSTRAINT AVCON_1204638256_DOCU__000 CHECK (DOCU_TYPE IN ('DOCU', 'INDO', 'EXDO', 'FIDO')))
/
PROMPT Creating Check Constraint on 'QUOTES'
ALTER TABLE QUOTES
ADD (CONSTRAINT AVCON_1204630230_QUTE__000 CHECK (QUTE_TYPE IN ('AQ', 'MQ', 'QUTE')))
ADD (CONSTRAINT AVCON_1204638256_QUTE__000 CHECK (QUTE_TYPE IN ('AQ', 'MQ', 'QUTE')))
/
PROMPT Creating Check Constraint on 'PARTY_RELATIONSHIPS'
@@ -575,17 +575,17 @@ to_parl_rt_code = to_prtp_rt_code))
PROMPT Creating Check Constraint on 'PARTIES'
ALTER TABLE PARTIES
ADD (CONSTRAINT AVCON_1204630230_TRIPA_000 CHECK (TRIPARTITE_MEMBER IN ('YES', 'NO')))
ADD (CONSTRAINT AVCON_1204638256_TRIPA_000 CHECK (TRIPARTITE_MEMBER IN ('YES', 'NO')))
/
PROMPT Creating Check Constraint on 'PARTIES'
ALTER TABLE PARTIES
ADD (CONSTRAINT AVCON_1204630230_STATU_000 CHECK (STATUS IN ('OPEN', 'EXPIRED', 'LOCKED')))
ADD (CONSTRAINT AVCON_1204638256_STATU_000 CHECK (STATUS IN ('OPEN', 'EXPIRED', 'LOCKED')))
/
PROMPT Creating Check Constraint on 'PARTIES'
ALTER TABLE PARTIES
ADD (CONSTRAINT AVCON_1204630230_PRTY__000 CHECK (PRTY_TYPE
ADD (CONSTRAINT AVCON_1204638256_PRTY__000 CHECK (PRTY_TYPE
IN ('PRTY', 'IO', 'EO', 'MKTP', 'PERS', 'MANU', 'NEMP', 'EMP', 'ORG'
)))
/
@@ -603,82 +603,82 @@ OR
PROMPT Creating Check Constraint on 'DOCUMENT_ROLES'
ALTER TABLE DOCUMENT_ROLES
ADD (CONSTRAINT AVCON_1204630230_DORO__000 CHECK (DORO_TYPE IN ('DRRO', 'DORO', 'ENDO', 'QUDO')))
ADD (CONSTRAINT AVCON_1204638256_DORO__000 CHECK (DORO_TYPE IN ('DRRO', 'DORO', 'ENDO', 'QUDO')))
/
PROMPT Creating Check Constraint on 'QUOTE_ITEMS'
ALTER TABLE QUOTE_ITEMS
ADD (CONSTRAINT AVCON_1204630230_QUIT__000 CHECK (QUIT_TYPE IN ('LQI', 'AQI', 'BQI', 'MQI', 'QUIT', 'HQI')))
ADD (CONSTRAINT AVCON_1204638256_QUIT__000 CHECK (QUIT_TYPE IN ('LQI', 'AQI', 'BQI', 'MQI', 'QUIT', 'HQI')))
/
PROMPT Creating Check Constraint on 'ROLE_TYPES'
ALTER TABLE ROLE_TYPES
ADD (CONSTRAINT AVCON_1204630230_RT_TY_000 CHECK (RT_TYPE IN ('DORT', 'PART', 'RT', 'PCMRT', 'QURT', 'ENRT', 'PRT')))
ADD (CONSTRAINT AVCON_1204638256_RT_TY_000 CHECK (RT_TYPE IN ('DORT', 'PART', 'RT', 'PCMRT', 'QURT', 'ENRT', 'PRT')))
/
PROMPT Creating Check Constraint on 'ENQUIRIES'
ALTER TABLE ENQUIRIES
ADD (CONSTRAINT AVCON_1204630230_DOWNS_000 CHECK (DOWNSTREAM_BOOSTER_OR_COMPRESS IN ('YES', 'NO')))
ADD (CONSTRAINT AVCON_1204638256_DOWNS_000 CHECK (DOWNSTREAM_BOOSTER_OR_COMPRESS IN ('YES', 'NO')))
/
PROMPT Creating Check Constraint on 'ENQUIRIES'
ALTER TABLE ENQUIRIES
ADD (CONSTRAINT AVCON_1204630230_INDIC_000 CHECK (INDICATIVE_TIME IN ('DY', 'AM', 'PM')))
ADD (CONSTRAINT AVCON_1204638256_INDIC_000 CHECK (INDICATIVE_TIME IN ('DY', 'AM', 'PM')))
/
PROMPT Creating Check Constraint on 'ENQUIRIES'
ALTER TABLE ENQUIRIES
ADD (CONSTRAINT AVCON_1204630230_HOUSI_000 CHECK (HOUSING_REQUIRED IN ('YES', 'NO')))
ADD (CONSTRAINT AVCON_1204638256_HOUSI_000 CHECK (HOUSING_REQUIRED IN ('YES', 'NO')))
/
PROMPT Creating Check Constraint on 'ENQUIRIES'
ALTER TABLE ENQUIRIES
ADD (CONSTRAINT AVCON_1204630230_BASE__000 CHECK (BASE_REQUIRED IN ('YES', 'NO')))
ADD (CONSTRAINT AVCON_1204638256_BASE__000 CHECK (BASE_REQUIRED IN ('YES', 'NO')))
/
PROMPT Creating Check Constraint on 'ENQUIRIES'
ALTER TABLE ENQUIRIES
ADD (CONSTRAINT AVCON_1204630230_CONVE_000 CHECK (CONVERTOR_REQUIRED IN ('YES', 'NO')))
ADD (CONSTRAINT AVCON_1204638256_CONVE_000 CHECK (CONVERTOR_REQUIRED IN ('YES', 'NO')))
/
PROMPT Creating Check Constraint on 'ENQUIRIES'
ALTER TABLE ENQUIRIES
ADD (CONSTRAINT AVCON_1204630230_AMR_R_000 CHECK (AMR_REQUIRED IN ('YES', 'NO')))
ADD (CONSTRAINT AVCON_1204638256_AMR_R_000 CHECK (AMR_REQUIRED IN ('YES', 'NO')))
/
PROMPT Creating Check Constraint on 'ENQUIRIES'
ALTER TABLE ENQUIRIES
ADD (CONSTRAINT AVCON_1204630230_EMS_R_000 CHECK (EMS_REQUIRED IN ('YES', 'NO')))
ADD (CONSTRAINT AVCON_1204638256_EMS_R_000 CHECK (EMS_REQUIRED IN ('YES', 'NO')))
/
PROMPT Creating Check Constraint on 'ENQUIRIES'
ALTER TABLE ENQUIRIES
ADD (CONSTRAINT AVCON_1204630230_TWIN__000 CHECK (TWIN_STREAM_REQUIRED IN ('YES', 'NO')))
ADD (CONSTRAINT AVCON_1204638256_TWIN__000 CHECK (TWIN_STREAM_REQUIRED IN ('YES', 'NO')))
/
PROMPT Creating Check Constraint on 'ENQUIRIES'
ALTER TABLE ENQUIRIES
ADD (CONSTRAINT AVCON_1204630230_EXIST_000 CHECK (EXISTING_LOGGER IN ('YES', 'NO')))
ADD (CONSTRAINT AVCON_1204638256_EXIST_000 CHECK (EXISTING_LOGGER IN ('YES', 'NO')))
/
PROMPT Creating Check Constraint on 'ENQUIRIES'
ALTER TABLE ENQUIRIES
ADD (CONSTRAINT AVCON_1204630230_LOAD__000 CHECK (LOAD_CONTROL_TYPE IN ('Constant', 'On/Off', 'Modulating')))
ADD (CONSTRAINT AVCON_1204638256_LOAD__000 CHECK (LOAD_CONTROL_TYPE IN ('Constant', 'On/Off', 'Modulating')))
/
PROMPT Creating Check Constraint on 'ENQUIRIES'
ALTER TABLE ENQUIRIES
ADD (CONSTRAINT AVCON_1204630230_EXIST_001 CHECK (EXISTING_METER_OWNER IN ('S', 'T', 'C')))
ADD (CONSTRAINT AVCON_1204638256_EXIST_001 CHECK (EXISTING_METER_OWNER IN ('S', 'T', 'C')))
/
PROMPT Creating Check Constraint on 'ENQUIRIES'
ALTER TABLE ENQUIRIES
ADD (CONSTRAINT AVCON_1204630230_EXIST_002 CHECK (EXISTING_CONVERTOR IN ('YES', 'NO')))
ADD (CONSTRAINT AVCON_1204638256_EXIST_002 CHECK (EXISTING_CONVERTOR IN ('YES', 'NO')))
/
PROMPT Creating Check Constraint on 'ENQUIRIES'
ALTER TABLE ENQUIRIES
ADD (CONSTRAINT AVCON_1204630230_MARKE_000 CHECK (MARKET_SECTOR_CODE IN ('I', 'D')))
ADD (CONSTRAINT AVCON_1204638256_MARKE_000 CHECK (MARKET_SECTOR_CODE IN ('I', 'D')))
/
PROMPT Creating Check Constraint on 'REGI_ENQU_EXCLUSIONS'
@@ -1255,6 +1255,20 @@ ALTER TABLE ENQUIRIES ADD (CONSTRAINT
(CODE))
/
PROMPT Creating Foreign Key on 'ENQUIRIES'
ALTER TABLE ENQUIRIES ADD (CONSTRAINT
ENQU_PRTY_FK FOREIGN KEY
(EXISTING_PRTY_ID) REFERENCES PARTIES
(ID))
/
PROMPT Creating Foreign Key on 'ENQUIRIES'
ALTER TABLE ENQUIRIES ADD (CONSTRAINT
ENQU_METR_FK FOREIGN KEY
(EXISTING_METR_CODE) REFERENCES METERS
(CODE))
/
PROMPT Creating Foreign Key on 'RELIEF_VALVES'
ALTER TABLE RELIEF_VALVES ADD (CONSTRAINT
REVA_RVTY_FK FOREIGN KEY

View File

@@ -1,6 +1,6 @@
-- C:\Andy\svn\WEBMIP\Schema\mip.ind
--
-- Generated for Oracle 10g on Tue Mar 04 11:30:31 2008 by Server Generator 10.1.2.6.18
-- Generated for Oracle 10g on Tue Mar 04 13:44:17 2008 by Server Generator 10.1.2.6.18
PROMPT Creating Index 'REGU_RETY_FK_I'
@@ -399,6 +399,11 @@ CREATE INDEX ENQU_MESC_EXISTING_FK_I ON ENQUIRIES
(EXISTING_MESC_CODE)
/
PROMPT Creating Index 'ENQU_METR_FK_I'
CREATE INDEX ENQU_METR_FK_I ON ENQUIRIES
(EXISTING_METR_CODE)
/
PROMPT Creating Index 'ENQU_ENTY_FK_I'
CREATE INDEX ENQU_ENTY_FK_I ON ENQUIRIES
(ENTY_CODE)
@@ -419,6 +424,11 @@ CREATE INDEX ENQU_COMT_AGENT_FK_I ON ENQUIRIES
(AGENT_COMT_CODE)
/
PROMPT Creating Index 'ENQU_PRTY_FK_I'
CREATE INDEX ENQU_PRTY_FK_I ON ENQUIRIES
(EXISTING_PRTY_ID)
/
PROMPT Creating Index 'ENQU_SVCP_REQUIRED_FK_I'
CREATE INDEX ENQU_SVCP_REQUIRED_FK_I ON ENQUIRIES
(REQUIRED_SVCP_CODE)

View File

@@ -1,6 +1,6 @@
-- C:\Andy\svn\WEBMIP\Schema\mip.sql
--
-- Generated for Oracle 10g on Tue Mar 04 11:30:31 2008 by Server Generator 10.1.2.6.18
-- Generated for Oracle 10g on Tue Mar 04 13:44:17 2008 by Server Generator 10.1.2.6.18
SPOOL mip.lst

View File

@@ -1,6 +1,6 @@
-- C:\Andy\svn\WEBMIP\Schema\mip.sqs
--
-- Generated for Oracle 10g on Tue Mar 04 11:30:31 2008 by Server Generator 10.1.2.6.18
-- Generated for Oracle 10g on Tue Mar 04 13:44:17 2008 by Server Generator 10.1.2.6.18
PROMPT Creating Sequence 'FLTR_SEQ'
CREATE SEQUENCE FLTR_SEQ

View File

@@ -1,6 +1,6 @@
-- C:\Andy\svn\WEBMIP\Schema\mip.tab
--
-- Generated for Oracle 10g on Tue Mar 04 11:30:30 2008 by Server Generator 10.1.2.6.18
-- Generated for Oracle 10g on Tue Mar 04 13:44:16 2008 by Server Generator 10.1.2.6.18
@@ -553,6 +553,8 @@ CREATE TABLE ENQUIRIES
,ENTY_CODE VARCHAR2(80)
,EXISTING_MESC_CODE VARCHAR2(80)
,EXISTING_METY_CODE VARCHAR2(80)
,EXISTING_METR_CODE VARCHAR2(80)
,EXISTING_PRTY_ID NUMBER
,REQUIRED_MESC_CODE VARCHAR2(80)
,REQUIRED_SVCP_CODE VARCHAR2(80)
,AGENT_CONTACT_VALUE VARCHAR2(240)
@@ -611,7 +613,6 @@ CREATE TABLE ENQUIRIES
,QMIN NUMBER
,LOAD_CONTROL_TYPE VARCHAR2(10)
,EXISTING_METER_SERIAL_NO VARCHAR2(30)
,EXISTING_METER_MODEL VARCHAR2(20)
,EXISTING_METER_OWNER VARCHAR2(1)
,EXISTING_METER_ASSET_PROVIDER VARCHAR2(210)
,EXISTING_CONVERTOR VARCHAR2(3)