Addressed #351 by adding existing_prty_id to calc_meter_reqs (similar change to screen 32).

git-svn-id: http://locode01.ad.dom/svn/WEBMIP/trunk@4022 248e525c-4dfb-0310-94bc-949c084e9493
This commit is contained in:
hardya
2008-03-17 14:10:40 +00:00
parent ac1542500f
commit 54a2987177

View File

@@ -12,8 +12,7 @@ CREATE OR REPLACE PACKAGE mip_enquiry IS
,existing_mesc_code meters.mesc_code%TYPE ,existing_mesc_code meters.mesc_code%TYPE
,existing_mety_code meters.mety_code%TYPE ,existing_mety_code meters.mety_code%TYPE
,existing_prty_id meters.prty_id%TYPE ,existing_prty_id meters.prty_id%TYPE
,required_mesc_code meters.mesc_code%TYPE ,required_mesc_code meters.mesc_code%TYPE);
);
-- Public function and procedure declarations -- Public function and procedure declarations
FUNCTION delete_enquiry(p_enquiryid IN NUMBER) RETURN BOOLEAN; FUNCTION delete_enquiry(p_enquiryid IN NUMBER) RETURN BOOLEAN;
@@ -64,6 +63,7 @@ CREATE OR REPLACE PACKAGE mip_enquiry IS
,p_required_mesc_code meters.mesc_code%TYPE ,p_required_mesc_code meters.mesc_code%TYPE
,p_existing_metr_code meters.code%TYPE ,p_existing_metr_code meters.code%TYPE
,p_existing_mety_code meters.mety_code%TYPE ,p_existing_mety_code meters.mety_code%TYPE
,p_existing_prty_id meters.prty_id%TYPE
,p_qmax meters.qmax%TYPE) ,p_qmax meters.qmax%TYPE)
RETURN t_rec_meter_reqs; RETURN t_rec_meter_reqs;
@@ -426,6 +426,7 @@ CREATE OR REPLACE PACKAGE BODY mip_enquiry IS
,p_required_mesc_code meters.mesc_code%TYPE ,p_required_mesc_code meters.mesc_code%TYPE
,p_existing_metr_code meters.code%TYPE ,p_existing_metr_code meters.code%TYPE
,p_existing_mety_code meters.mety_code%TYPE ,p_existing_mety_code meters.mety_code%TYPE
,p_existing_prty_id meters.prty_id%TYPE
,p_qmax meters.qmax%TYPE) ,p_qmax meters.qmax%TYPE)
RETURN t_rec_meter_reqs IS RETURN t_rec_meter_reqs IS
l_dummy NUMBER; l_dummy NUMBER;
@@ -501,6 +502,7 @@ CREATE OR REPLACE PACKAGE BODY mip_enquiry IS
l_rec_meter_reqs.existing_metr_code := 'OTHER'; l_rec_meter_reqs.existing_metr_code := 'OTHER';
l_rec_meter_reqs.existing_mety_code := p_existing_mety_code; l_rec_meter_reqs.existing_mety_code := p_existing_mety_code;
l_rec_meter_reqs.existing_mesc_code := p_existing_mesc_code; l_rec_meter_reqs.existing_mesc_code := p_existing_mesc_code;
l_rec_meter_reqs.existing_prty_id := p_existing_prty_id;
END IF; END IF;
END IF; END IF;